SITE MAP
MEASUREMENT / PERIPHERALS

Peripherals

A range of units that support measurement instruments, from USB-powered devices to preamplifiers, power supplies and connector conversion boxes.

1 — USB DEVICE

USB-Powered Devices

Pocket MCA PMCA01

PMCA01 unit
  • ModelPMCA01 (Former model: PMCAX-CH01-01)
  • ApplicationCompact MCA for educational use
  • Power supplyUSB bus power
  • SoftwarePublic API supported (GitHub: anseen-inc/PMCA)
  • PriceContact us
2 — PREAMPLIFIER

Preamplifiers

Preamplifier for Semiconductor Detectors CSP02

CSP02 unit
  • ModelCSP02 (Former model: CSP-BNC-02)
  • ApplicationFor low-leakage-current, low-capacitance detectors such as CdTe detectors; fast rise time (supports 100MHz sampling by waveform analyzers)
  • Noise350 electrons FWHM@0pF / 800 electrons FWHM@100pF (typ.)
  • Rise time6ns@0pF / 60ns@100pF (typ.)
  • PriceContact us

Measurement example: The rising edge of pulse signals was observed using a Schottky-type CdTe detector biased at 700V with a Cs-137 source. The fast rise due to electrons (5ns) and the slow rise due to holes (55ns) can be clearly distinguished, and by feeding the signal into a waveform analyzer, waveform analysis can be performed taking advantage of 100MHz sampling.

Compact Preamplifier CSP04

CSP04 unit
  • ModelCSP04
  • ApplicationsSemiconductor detectors, remote measurement
  • FeaturesRemote measurement over 10 m via RJ45 cable
  • Enclosure Size3 cm × 3 cm × 9 cm (excluding protrusions)
  • PriceContact us

Photomultiplier Tube Preamplifier AMP01

AMP01 unit
  • ModelAMP01 (Former model: AMP-BNC-01)
  • ApplicationExtending photomultiplier tube output
  • Gain10V/V@50Ω / 0.5mV/µA@50Ω
  • Rise time5ns or less
  • -3dB bandwidth100MHz
  • PriceContact us

Preamplifier for Photomultiplier Tubes AMP03

AMP03 unit
  • ModelAMP03 (Former model: AMP-BNC-03)
  • ApplicationOutput shaping for photomultiplier tubes
  • Circuit configurationCharge-sensitive amplifier
  • Gain10mV/pC@HiZ
  • Integration time constant1ms (100pF // 10MΩ)
  • PriceContact us
3 — POWER SUPPLY

Power Supplies

Bias Power Supply for Photomultiplier Tubes HV01

HV01-P / HV01-N unit
  • ModelHV01-P / HV01-N (Former model: HVP-SHV-01 / HVN-SHV-01)
  • ApplicationBias power supply for photomultiplier tubes (PMTs)
  • Output voltage range200 to 1100V (polarity specified at time of order)
  • PriceContact us

Bias Power Supply for Semiconductor Detectors HV02

HV02-P / HV02-N unit
  • ModelHV02-P / HV02-N (Former model: HVP-SHV-02 / HVN-SHV-02)
  • ApplicationBias power supply for semiconductor detectors
  • Output voltage range240 to 1400V (polarity specified at time of order)
  • PriceContact us

Preamplifier Power Supply (+/-12V) PPS01

PPS01 unit
  • ModelPPS01
  • ApplicationPower supply for preamplifiers (DSUB 9-pin connector)
  • Output±12V (DSUB 9-pin, NIM pin assignment) / 100mA each
  • PriceContact us
4 — CONNECTOR BOX

Connector Conversion Boxes

RJ45 Connector Conversion Box CBX01

  • ModelCBX01
  • ApplicationConnects the compact preamplifier CSP04 to existing main amplifiers and other equipment
  • ConversionConverts BNC (signal), DSUB (preamplifier power ±12V), and two auxiliary voltage inputs (banana) to RJ45
  • PriceContact us

SHV Connector Splitter Box (1:2) CBX02

  • ModelCBX02
  • ApplicationSplitting SHV cables (1:2) (alternative to T-connectors)
  • ConfigurationSHV connector (jack) × 3
  • PriceContact us
5 — CUSTOM DEVELOPMENT

Special-Purpose Developments

TTL Signal Isolator TTLISO-BNC-01

TTLISO-BNC-01 unit
  • ModelTTLISO-BNC-01
  • ApplicationIsolation of high-speed TTL signals
  • Supported pulse width90ns or more
  • Power supplyPowered from the signal output side
  • PriceContact us
6 — DISCONTINUED

Discontinued Products

Legacy products that are no longer sold. Specifications are provided for reference only.

Preamplifier for Semiconductor Detectors CSP-BNC-01Discontinued

  • ModelCSP-BNC-01
  • ApplicationFor low-leakage-current, low-capacitance detectors such as CdTe detectors
  • Noise3.0keV FWHM@0pF / 5.0keV FWHM@100pF (with CdTe)

AC-Coupled Amplifier AMP02Discontinued

  • ModelAMP02 (Former model: AMP-BNC-02)
  • ApplicationRadiation measurement
  • High-voltage signal path500Vdc withstand voltage, 0.1mVac, gain of 10000x
  • Low-voltage signal path2Vdc withstand voltage, 1Vac, gain of 1x
  • Rise time5ns@0pF